Diagram of an energy management information system: meters and sub-meters, building and process controls and production data flow into analytics that produce dashboards, alerts and fault diagnostics, leading to actions and verified savings
Software guide

Energy Monitoring Platforms (EMIS): A Practical Buyer’s Guide

Energy monitoring software, often called an energy management information system (EMIS), turns meter and system data into information people can act on. Results vary widely: some sites cut consumption steadily, others collect data that nobody reads. This guide explains the main types of EMIS, what public data from a large US Department of Energy campaign shows, and how to choose and use a platform.

What an EMIS is

In the US Department of Energy's Smart Energy Analytics Campaign report, prepared by Lawrence Berkeley National Laboratory (LBNL), EMIS covers two main tool types. Energy information systems (EIS) are the software, data acquisition hardware and communication systems used to store, analyze and display energy data. Fault detection and diagnostic (FDD) tools are software that automates detecting faults and suboptimal performance of building systems and helps diagnose their causes.

In industry, the same idea extends to process and utility data: compressed air, steam, chillers, furnaces and production volumes, so energy can be normalized per unit of output.

What the public evidence shows

The 2016 to 2020 Smart Energy Analytics Campaign worked with 104 commercial organizations, more than 6,500 buildings and 567 million square feet of floor area, which LBNL describes as the most comprehensive dataset assembled on analytics installation and use. By the second year after installation, participants with EIS achieved median annual energy savings of 3%, and participants with FDD tools achieved median savings of 9%. LBNL projected savings of 4.1 trillion Btu and $95 million a year once EMIS use is established across participants, and reported a median two-year simple payback. The report notes that savings were measured at whole-building level and cannot be attributed solely to the EMIS.

The DOE Federal Energy Management Program adds that in 2020, campaign participants using automated FDD achieved median annual savings of $0.27 per square foot, against deployment and recurring costs of $0.05 and $0.07 per square foot. The top three measures reported were improved HVAC scheduling, space temperature adjustments and correcting simultaneous heating and cooling: operational fixes, not capital projects.

These are building results, mostly from offices and universities. Industrial sites should treat them as a sign of what disciplined use of data can deliver, not as a promise.

Comparison of utility bills and spreadsheets, energy information systems, and fault detection and diagnostics tools
More automation finds more, but only if someone acts.

Options compared

CriterionBills and spreadsheetsEnergy information system (EIS)Fault detection and diagnostics (FDD)
Data resolutionMonthly15-minute or hourly interval dataSystem-level trend data, often minutes
What it findsBig trends, tariff issuesBaseload, schedules, spikes, driftSpecific equipment faults and control errors
Effort to actHigh (manual analysis)MediumLower: findings are prioritized
IntegrationNoneMeters, sub-meters, sometimes BMSBMS or controls points, equipment models
Median savings in DOE campaignNot measured3% (by year two)9% (by year two)

Savings figures from the LBNL Smart Energy Analytics Campaign report (buildings); other rows are indicative.

Selection criteria

  1. Metering plan first. Which significant energy uses need sub-meters? Monitoring the main meter alone rarely shows where waste is.
  2. Normalization. Energy per unit, per degree-day or per shift, so performance is comparable over time. This links directly to an energy baseline and EnPIs.
  3. Alerts and rules. Out-of-hours consumption, baseload creep, demand peaks. Alerts must reach someone who can act.
  4. Analytics depth. Load profiles, regression models, and for buildings, FDD rules for HVAC.
  5. Openness. Standard protocols, data export and API access so you are not locked in.
  6. Measurement and verification. Can it document savings from projects?
  7. Total cost and support. Meters, gateways, installation, subscriptions and the analyst time to use it.
Video: Using Energy Management and Information Systems (EMIS) for Emissions Reduction by Better Buildings & Better Plants (US DOE) (YouTube). Click to play; nothing loads from YouTube until you do.

Getting value from the data

The LBNL report frames EMIS as most effective when combined with a monitoring-based commissioning process: regular review of findings, a prioritized action list and follow-up. In practice:

  • Hold a short weekly energy review with operations and maintenance.
  • Keep an energy action register with owners and expected savings.
  • Check load profiles for nights, weekends and changeovers. The Weekend Watt Hunt kit gives a structured way to find what runs when nothing should.
  • Track demand charges and peaks if your tariff penalizes them.
  • Feed results into your energy management system; see our guide to ISO 50001.

Pros and cons

Pros: visibility of waste, faster detection of drift, evidence for projects, and data for energy reporting. Cons: metering and integration cost, alert fatigue, and the analyst time required. Without an owner and a routine, an EMIS becomes an expensive chart.

Questions to ask vendors

  • Which meters, protocols and building or process control systems can you read natively?
  • How are baselines built and adjusted for production, weather and shifts?
  • Show an alert from detection to closed action, including who received it and what was done.
  • How do you document savings for a project, and which method do you use?
  • Can we export raw interval data at any time, in a standard format?
  • What is included in the subscription, and what costs extra (meters, gateways, analyst services)?

Industrial specifics

Plants differ from office buildings in three ways that matter for EMIS selection. Energy use follows production more than weather, so normalization by output is essential. Large single loads such as compressors, chillers, furnaces and dryers deserve their own meters and often their own efficiency indicators, for example specific power for compressed air. And production schedules change, so the system must handle shifts, weekends and changeovers when deciding what counts as waste. Ask for examples from plants with a similar process, not just from commercial buildings.

Common mistakes

  • Buying software before deciding which loads to meter.
  • No normalization, so production changes hide real performance.
  • Alerts sent to a shared inbox nobody reads.
  • Treating EMIS as an IT project rather than an operations routine.

Related free tools

Sources and further reading

Frequently asked questions

What is the difference between EIS and FDD?
According to the LBNL campaign report, EIS store, analyze and display energy data, while FDD tools automatically detect faults and suboptimal performance in building systems and help diagnose causes.
How much can an EMIS save?
In the US DOE Smart Energy Analytics Campaign, median savings by year two were 3% with EIS and 9% with FDD in commercial buildings. Results depend on how actively findings are acted on.
Do we need sub-meters?
Usually yes for significant energy uses. A single main meter shows totals but rarely where the waste is.
Is an EMIS required for ISO 50001?
No. ISO 50001 needs monitoring and measurement appropriate to your energy uses; an EMIS is one way to do it efficiently.
Who should own the EMIS?
An energy manager or engineer should own the analytics and the action list, but findings must be assigned to operations and maintenance people who can change settings and fix equipment. Without that link, alerts pile up unread. A short weekly review with all three groups keeps the system useful.

Put it into practice

Free calculators and procedure generators for maintenance, reliability and continuous-improvement teams.

Explore the free tools →

Donate · Faire un don · تبرّع